16 research outputs found

    Modified protocol of omalizumab treatment to prevent carboplatin-induced drug hypersensitivity reactions:a case study

    Get PDF
    Carboplatin administration can usually be safely continued via a so-called desensitisation protocol when hypersensitivity reactions arise. Severe break-through reactions that occur early during desensitisation are likely to be IgE-mediated; in that case, addition of omalizumab premedication should be strongly considered

    Medical algorithm:Peri-operative management of mastocytosis patients

    Get PDF
    Mastocytosis is a clonal disorder characterized by the proliferation and accumulation of mast cells (MCs) in various tissue types, preferentially skinand bone marrow (BM). Mastocytosis consists of cutaneous and systemic forms in both pediatric and adult patients. Both the excess and increased propensity of MCs to release mediators leads to a higher frequency and severity ofimmediate hypersensitivity reactions.1-4

    Managing granulomatous-lymphocytic interstitial lung disease in common variable immunodeficiency disorders : e-GLILDnet International Clinicians Survey

    Get PDF
    Background Granulomatous-lymphocytic interstitial lung disease (GLILD) is a rare, potentially severe pulmonary complication of common variable immunodeficiency disorders (CVID). Informative clinical trials and consensus on management are lacking. Aims The European GLILD network (e-GLILDnet) aims to describe how GLILD is currently managed in clinical practice and to determine the main uncertainties and unmet needs regarding diagnosis, treatment and follow-up. Methods The e-GLILDnet collaborators developed and conducted an online survey facilitated by the European Society for Immunodeficiencies (ESID) and the European Respiratory Society (ERS) between February-April 2020. Results were analyzed using SPSS. Results One hundred and sixty-one responses from adult and pediatric pulmonologists and immunologists from 47 countries were analyzed. Respondents treated a median of 27 (interquartile range, IQR 82-maximum 500) CVID patients, of which a median of 5 (IQR 8-max 200) had GLILD. Most respondents experienced difficulties in establishing the diagnosis of GLILD and only 31 (19%) had access to a standardized protocol. There was little uniformity in diagnostic or therapeutic interventions. Fewer than 40% of respondents saw a definite need for biopsy in all cases or performed bronchoalveolar lavage for diagnostics. Sixty-six percent used glucocorticosteroids for remission-induction and 47% for maintenance therapy; azathioprine, rituximab and mycophenolate mofetil were the most frequently prescribed steroid-sparing agents. Pulmonary function tests were the preferred modality for monitoring patients during follow-up. Conclusions These data demonstrate an urgent need for clinical studies to provide more evidence for an international consensus regarding management of GLILD. These studies will need to address optimal procedures for definite diagnosis and a better understanding of the pathogenesis of GLILD in order to provide individualized treatment options. Non-availability of well-established standardized protocols risks endangering patients

    Valid and reliable instruments for arm-hand assessment at ICF activity level in persons with hemiplegia: a systematic review

    Get PDF
    Contains fulltext : 110141.pdf (publisher's version ) (Open Access)BACKGROUND: Loss of arm-hand performance due to a hemiparesis as a result of stroke or cerebral palsy (CP), leads to large problems in daily life of these patients. Assessment of arm-hand performance is important in both clinical practice and research. To gain more insight in e.g. effectiveness of common therapies for different patient populations with similar clinical characteristics, consensus regarding the choice and use of outcome measures is paramount. To guide this choice, an overview of available instruments is necessary. The aim of this systematic review is to identify, evaluate and categorize instruments, reported to be valid and reliable, assessing arm-hand performance at the ICF activity level in patients with stroke or cerebral palsy. METHODS: A systematic literature search was performed to identify articles containing instruments assessing arm-hand skilled performance in patients with stroke or cerebral palsy. Instruments were identified and divided into the categories capacity, perceived performance and actual performance. A second search was performed to obtain information on their content and psychometrics. RESULTS: Regarding capacity, perceived performance and actual performance, 18, 9 and 3 instruments were included respectively. Only 3 of all included instruments were used and tested in both patient populations. The content of the instruments differed widely regarding the ICF levels measured, assessment of the amount of use versus the quality of use, the inclusion of unimanual and/or bimanual tasks and the inclusion of basic and/or extended tasks. CONCLUSIONS: Although many instruments assess capacity and perceived performance, a dearth exists of instruments assessing actual performance. In addition, instruments appropriate for more than one patient population are sparse. For actual performance, new instruments have to be developed, with specific focus on the usability in different patient populations and the assessment of quality of use as well as amount of use. Also, consensus about the choice and use of instruments within and across populations is needed

    Robust estimation of bacterial cell count from optical density

    Get PDF
    Optical density (OD) is widely used to estimate the density of cells in liquid culture, but cannot be compared between instruments without a standardized calibration protocol and is challenging to relate to actual cell count. We address this with an interlaboratory study comparing three simple, low-cost, and highly accessible OD calibration protocols across 244 laboratories, applied to eight strains of constitutive GFP-expressing E. coli. Based on our results, we recommend calibrating OD to estimated cell count using serial dilution of silica microspheres, which produces highly precise calibration (95.5% of residuals <1.2-fold), is easily assessed for quality control, also assesses instrument effective linear range, and can be combined with fluorescence calibration to obtain units of Molecules of Equivalent Fluorescein (MEFL) per cell, allowing direct comparison and data fusion with flow cytometry measurements: in our study, fluorescence per cell measurements showed only a 1.07-fold mean difference between plate reader and flow cytometry data

    Azathioprine Hypersensitivity Syndrome in a Cohort of Antineutrophil Cytoplasmic Antibody-Associated Vasculitis Patients

    Get PDF
    BACKGROUND: Azathioprine hypersensitivity syndrome is a rare complication of azathioprine therapy. Its symptoms resemble infection or relapse of inflammatory disease, hindering correct diagnosis. Current literature is limited to sporadic case reports and reviews. OBJECTIVE: To estimate the incidence of azathioprine hypersensitivity syndrome and describe its characteristics in the context of an observational cohort of patients with antineutrophil cytoplasmic antibody (ANCA)-associated vasculitis. Also, to facilitate early recognition and awareness among clinicians. METHODS: Within a cohort of 290 patients with ANCA-associated vasculitis receiving azathioprine maintenance therapy, frequency of azathioprine hypersensitivity was described and characteristics were compared between hypersensitive and non-hypersensitive patients. Clinical picture, laboratory abnormalities, and concurrent medication of patients with azathioprine hypersensitivity were described. RESULTS: Of 290 patients, 25 (9%) experienced azathioprine hypersensitivity after a median of 14 (interquartile range [IQR] 12-18) days. Frequent symptoms were fever (100%), malaise (60%), arthralgia (36%), and rash (32%). All patients used prednisolone (median 10 mg/day, IQR 9.4-16.3 mg/day) at the time of the hypersensitivity reaction. Most patients had a rise in C-reactive protein (CRP), leukocyte counts, and neutrophil counts, but no eosinophilia. Thiopurine S-methyltransferase (TPMT) activity was significantly lower in hypersensitive patients (median 74.4 [IQR 58.0-80.1] nmol/gHb/L) compared with controls (median 81.4 [71.9-90.5] nmol/gHb/L), P = .01. Hypersensitive patients had a higher risk of relapse (hazard ratio 2.2, 95% confidence interval 1.2-4.2; P=.01). CONCLUSIONS: Azathioprine hypersensitivity syndrome is strikingly common in ANCA-associated vasculitis, might be associated with reduced TPMT activity, is accompanied by an increase in neutrophil counts, and may occur even during concomitant prednisolone therapy. Proper recognition may prevent unnecessary hospital procedures and damage to the patient. (C) 2018 American Academy of Allergy, Asthma & Immunolog
    corecore